180kW - 240kW

EXTREMO SERIES

DCEX 60/60 | 60/60/60/60

180kW - 240kW

The Extremo Series fast charger DC 180kW/240kW are especially designed to provide public transport vehicles and fleets with fast one stop charging service. The charging stations are equipped with big charger base, logistics, intelligent controls, back-end support and operations management, surveillance systems to cater a most efficient and safe one stop charging solution for growing public transport system and fleet support.

This can deploy charging network rapidly and effectively providing high-power quick charging service for electric vehicles. It has durable, robust, all-weather enclosure for indoor and outdoor use and support CCS-2 Standard.

  • 180KW/240KW HIGH POWER CHARGING
  • ROBUST, ALL-WEATHER ENCLOSURE FOR INDOOR AND OUTDOOR USE: IP54
  • EASY TO INSTALL AND MAINTENANCE
  • 200 A HIGH OUTPUT CURRENT
  • DOUBLE STANDARD AVAILABLE: CCS OR CHADEMO
  • 7” FULL COLOR TOUCHSCREEN DISPLAY
  • RFID READER
  • FRIENDLY HUMAN MACHINE INTERFACE
  • FUTURE PROOF CONNECTIVITY
  • OCPP 1.6 OR ABOVE
  • FUTURE PROOF DUE TO DC OUTPUT VOLTAGE RANGE FROM 200 TO 1000 VDC COMPATIBLE FOR ALL EV
  • MODULAR ARCHITECTURE
  • EV STANDARDS: IEC 62196, IEC 61851, JEVS G105

Technical Specifications

Capacity180kW | 240kW
Input Voltage (Vac)415 Vac +10% or -6%, 50 Hz
Input Frequency50 Hz
THD≤ 5% of Nominal Voltage
Power Factor≥ 0.99 (Full load)
Wires3 - Phase, 5 - Wire AC (L1, L2, L3, N and PE)
Output Voltage - DC (Vdc)200 -1000 vdc
Standard/ConnectorCCS-2 / CHAdeMO
Number of Gun1 to 4
Efficiency≥ 94 %
Safety ParametersOver Voltage, Under Voltage, Over Current, Short Circuit, Surge, Over Temperature, Ground Fault, Residual Current, Emergency shutdown, Electric shock
Display Screen7" TFT LCD Touch Screen
Languages- SupportedEnglish (Other language optional)
Push ButtonEmergency Stop (Mushroom type)
Charging OptionGrid Responsive metering.
Visual IndicationPresence of Input Supply, Errors Indicator, State of Charge.
User AuthenticationUsing mobile application or User Interface (OCPP gives only a field mandate, media to be used is open) / QR Code / RFID Card / Password Login
PaymentRFID Card Wallet or App Wallet / Service
Between EV Charger and EVIEC 62196, IEC 61851 for CCS-2 and JEVS G105 for CHAdeMO
Between EV and Central ServerOCPP V1.6 or above - 10/100 Base-T Ethernet (Standard) or Optical GSM Modem (2G/3G/4G) or WLAN(Optional)
ProtectionIP 54
CoolingForced Air Cooling
Charging Cable Length5 Meter
Operating Temperature 0° C to 55° C
Storage Temperature 0° C to 60° C
Humidity (Non-Condensing)5% to 95%